This how the Airwiz will inspect, diagnose, and repair your dryer vent problems to make sure your dryer vent is safe and up to code.

Air-duct-cleaning-dryer-cleaners-cleaning-air-ducts-air-ducts-cleaning-ducting-cleaning-Germantown-Rockville-Silver-spring-Gaithersburg-MD

These are some of the codes and guidelines that we have simplified to make it easier for homeowners to understand. We use IRC and IMC codes as well manufacturers, and the best practices to inspect dryer vents.

Air-duct-cleaning-dryer-cleaners-cleaning-air-ducts-air-ducts-cleaning-ducting-cleaning-Germantown-Rockville-Silver-spring-Gaithersburg-MD-near-me

We start with the basics:

• check for disconnected ducts
• moisture problems
• broken ducts
• clocks
• incorrect material

A clothes dryer will vent around a gallon of water for each load of laundry. If the dryer vent is disconnected and in a crawlspace, attic, or other building cavity, the potential for moisture-related damage is significant.
We found a lot of rotten roof sheeting because the dryer was venting inside the attic. Mold problems are common normally when a dryer is leaking air or venting inside the house.

The duct

According to the requirements of the 2009 International Residential Code (IRC) M1502, the clothes dryer exhaust duct should be made with metal, with No. 28-gauge thickness, a smooth interior finish, also a duct diameter of 4 inches.

Maximum Length
The design is very important in determining the length limitations. Short, straight, horizontal duct runs are really efficient. Exists some differences between manufacturers but best practice is a duct length of no more than 25 feet from the wall to the outlet terminal, including the equivalent length for any fittings. The 2012 IRC M1502.4.4.1 allows a maximum length of 35 feet from the connection until transition duct (from the dryer to the outlet terminal). The maximum length of the exhaust duct is reduced in accordance with the following:

 

The maximum length of the exhaust duct are not including the transition duct. If the exhaust duct is concealed within the building’s construction.

Transition: the most commonly overseen dryer vent problem

A transition is the visible part of duct connecting the dryer to the wall duct. It is allowed to be up to 8 feet long and should never go through the wall. Transition ducts must be visible and not concealed within construction.
Bigger part of ducts made of vinyl, nylon or foil are not recommended. If used, they will loose the warranty of most dryers. These flexible accordion type designs because:

• do not meet code sizing and material specifications
• they trap lint,
• obstruct the air flow
• clog the duct
• require the dryer to work harder
• longer to dry clothes
• cause increase of dryer’s temperature
• wastes energy

Not only is a poorly exhausting dryer less efficient, it can also be a fire hazard due to the flammability of the accumulated lint and the lack of fire resistance. The use of foil or PVC pipe in a dryer exhaust ducts is also not allowed by modern building standards.

Another good practice is to restrict the dryer exhaust duct from passing through an attached garage. Ducts in the garage or penetrating the walls or ceilings separating the dwelling from the garage must be constructed of minimum No. 26-gauge sheet steel or any other approved material, having no openings into the garage.

Duct support

The duct have to be secured in place and supported at intervals not to exceed 12 feet. A good practice recommends supports installed at 4-foot intervals. Sags in the duct must be avoided.
We find disconnected ducts inside the walls all the time, it’s a big repair that includes opening the walls, duct repair, drywall repair and painting. It could have been prevented if the ducts were properly supported.

Termination

WRONG TERMINATION

The termination outside the building should be located at least 3 feet from any other building opening, and at least 10 feet from an air conditioner or heat pump condenser. The duct termination should be fitted with a closeable damper (a backdraft damper).
A mesh may not be installed at the duct terminus (2009 IRC M1502.3), as it can trap debris, which poses a fire hazard.
• Check the termination for birds’ nests, debris and damage.

 

 

 

Clogs

The leading can cause of fires from clothes dryers is the failure to clean the lint and other debris that can accumulate in and around them. Inspectors can provide the following recommendations to their clients:

The 10 top dryer vent problems:

Good practices:
• Keep clean the lint filter before or after each load of laundry.
• Remove any visible lint within the dryer.
• At least once a year, call a professional technician clean the dryer exhaust pipe.
• Gas dryers have to be cleaned and serviced regularly by a professional.
• Install a smoke alarm in your laundry area.
• Install a CO alarm in your laundry area for a gas dryer.
Call or email Airwiz to have your dryer inspected or cleaned if you prefer a professional to do this job for you.

References
ENERGY STAR Version 3, (Rev. 07)
HVAC System Quality Checklist, Local Mechanical Exhaust. Clothes dryers vented directly to outdoors, unless for ventless dryers equipped with a condensate drain.
2009 IECC
This topic is not specifically addressed in the 2009 IECC.
2009 IRC
Section M1502.2 Independent exhaust system. Dryer exhaust systems to be independent of all other systems and convey the moisture to the outdoors, except listed and labeled condensing (ductless) dryers are used.
2012 IECC
This topic is not specifically addressed in the 2012 IECC.
2012 IRC
Section M1502.2 Independent exhaust system. Dryer exhaust systems to be independent of all other systems and convey the moisture to the outdoors, except listed and labeled condensing (ductless) dryers are used.